A glucose meter is a medical device for determining the approximate concentration of glucose in the blood. It can also be a strip of glucose paper dipped into a substance and measured to the glucose chart. It is a key element of home blood glucose monitoring by people with diabetes mellitus or hypoglycemia

Enabling frequent blood glucose monitoring at home using a truly non-invasive device
free download

Background Conventional invasive Blood Glucose (BG) monitoring approach suffers from under-utilization, mainly due to its painful, costly and complex manner of use. BG monitors, that are painless, easy and simple to use, with acceptable accuracy, are likely to overcome

Accuracy of a novel factory-calibrated continuous glucose monitoring device in normal glucose levels: a pilot study
free download

Free Style Libre Pro, a novel continuous glucose monitoring (CGM) device for retrospective assessment of glycemic excursion, does not require calibration during the measurement period. In this study, the accuracy of FreeStyle Libre Pro in normal glucose levels was

Optimising the glucose sampling performance of an intravascular microdialysis-based Continuous Glucose Monitoring device for use in hospital settings
free download

Page 1. March 2nd Optimising the glucose sampling performance of an intravascular microdialysis-based Continuous Glucose Monitoring device for use in hospital settings Fausto Lucarelli Cosimo Scuffi Julia K. Mader Felix Aberer Stefan Korsatko Francesco

Blood Glucose Monitoring Performance of Roche Accu-Check Go Glucometer Device at Moderately High Altitude
free download

Methods: Fasting blood glucose measurements were made simultaneously by Accucheck go glucometer device and standard laboratory methods in a group of 204 male and female patients residing in Erzurum, a province in Eastern Turkey with an altitude of 2000 meters

Repeatability of a Non-Invasive Glucose Monitoring Device
free download

According to the International Organization for Standardization (ISO) standard 1519 a repeatability test should be conducted to ensure that invasive blood glucose monitoring devices produce consistent repeatable measurements under similar conditions. Although no

Invasive Glucose Monitoring Device Measuring at the Earlobe can be Performed using Different Invasive Glucose Monitoring Methods without Loss or Device
free download

Introduction Regular glucose monitoring is essential for effective diabetes management. Therefore, numerous devices have been developed in order to ensure accurate measurements of blood glucose (BG) levels to reduce the risk for long term diabetes

Portable point-of-care device as alternative tool for monitoring blood glucose in lambari Astyanax altiparanae: stress and sex-specific effects
free download

The efficacy of a point-of-care (POC) blood glucometer (Accu-Chek Active) was evaluated in adult lambaris (Astyanax altiparanae), comparing the values obtained by this equipment to those obtained by the laboratory enzymatic method. The glycemia of adult males and

Non-Invasive Glucose Monitoring Device : Reducing Impact of Post-prandial Lagging Effect During Measurement
free download

GlucoTrack is a non-invasive (NI) home-use device for self- monitoring of glucose level. The device tracks physiological changes which are correlated with glucose excursions by measuring ultrasonic, electromagnetic and thermal parameters of the earlobe tissue. The

Towards a Miniature Long Term Continuous Glucose Monitoring Device : In vitro and In vivo Studies
free download

As of 200 according to Center for Disease Control and Prevention (CDC), estimated 20.8 million people (7% of the population) have diabetes in the United States alone. In 200 22 092 people died due to complications related to diabetes (www. cdc. gov). Though

EXPLORING THE ACCURACY OF A CONTINUOUS GLUCOSE MONITORING DEVICE AMONG DIABETIC PATIENTS ON HEMODIALYSIS
free download

Introduction: Among diabetic patients on maintenance hemodialysis, assessment of glycemic control status with the use of currently widely applied glycemic control indices is of limited diagnostic accuracy [1-3]. Evaluation of short-term glucose variability with continuous

Performance Evaluation of a New Non-Invasive Glucose Monitoring Device in Different Patient Subtypes During Standardized Meal Experiments
free download

Background Patients with insulin-treated diabetes mellitus have to perform regular blood glucose self-testing several times a day. Capillary blood samples are obtained by pricking the fingertip, which is considered to be the most painful procedure during daily routine. This

Evaluating the relationship of fasting capillary and venous blood sugar level in self- glucose monitoring device , fasting plasma glucose level and glycosylated
free download

Background As International Diabetes Federation (2013), declared that approximately 50% of all people with diabetes live in just three countries: China (98.4 million), India (65.1 million) and the USA (24.4 million). As already reported WHO (2014) 9% of adults 18 years

Accuracy Evaluation of the TrueTrack Smart System : Results of a New Blood Glucose Monitoring Device Suitable for Fingertip and Forearm Testing
free download

CONCLUSIONS: In this study, the TrueTrack Smart System was compared to state-of-the- art blood glucose monitoring systems with known, high levels of technical performance and market acceptance. During the entire statistical analysis, the TrueTrack Smart System

Amperometric glucose sensor for real time extracellular glucose monitoring in microfluidic device
free download

We have combined a microfluidic network and developed a miniature glucose sensor to measure glucose consumption of single cardiomyocytes in a confined extracellular space. The thin film glucose sensor was integrated into a 360 picoliter extracellular space. We used

A wireless implantable microbiosensor device for continuous glucose monitoring (CGM).
free download

Diabetes Mellitus is a chronic disease characterized by poor glucose regulation. On a long term, diabetes can lead to severe complications such as nephropathies, neuropathies, blindness and cardiovascular disorders. It is currently a leading cause of death, worldwide

A REVIEW OF RETROSPECTIVE, CONTINUOUS GLUCOSE MONITORING : AN EXAMPLE OF A MEDICAL DEVICE WHERE THE TYPICAL PRIMARY
free download

OBJECTIVES: To investigate the effectiveness of a pay-for-performance program (P4P) to increase quality care processes and decrease hospitalization among diabetics. METHODS: The study sample consisted of diabetic members 18 to 75 years of age enrolled in a

NIBG: an efficient near-infrared spectroscopy-based device for tele- monitoring blood glucose level of diabetes outpatients in an e-health system
free download

Major conventional blood glucose measuring systems pose a lot of inconveniences to diabetes patients, such as recurring pains incurred from finger-prick, infections from biosensor implant into the subcutaneous tissue, recurring costs incurred from the purchase

Design and development of a miniaturised flow-through measuring device for the in vivo monitoring of glucose and lactate
free download

7.2.4. A lightweight measuring device for the continous monitoring of glucose (Minimal)-invasive methods measure analyte concentration in the interstitial fluid of the skin (transcutaneous) or in the subcutis (subcutaneous). An example of a transcutaneous device for